Schedule 2 |
| Contaminant | Monitoring method | |
|---|---|---|
| Carbon monoxide | Australian Standard AS 3580.7.1:1992, Methods for sampling and analysis of ambient air—Determination of carbon monoxide—Direct-reading instrumental method | |
| Nitrogen dioxide | Australian Standard AS 3580.5.1:1993, Methods for sampling and analysis of ambient air—Determination of oxides of nitrogen—Chemiluminescence method | |
| Ozone | Australian Standard AS 3580.6.1:1990, Methods for sampling and analysis of ambient air—Determination of ozone—Direct-reading instrumental method | |
| PM10 | United States Code of Federal Regulations, Title 40—Protection of Environment, Volume 2, Part 50, Appendix J—Reference method for the determination of particulate matter as PM10 in the atmosphere; or | |
| Australian/New Zealand Standard AS/NZS 3580.9.6:2003, Methods for sampling and analysis of ambient air—Determination of suspended particulate matter—PM10 high volume sampler with size-selective inlet—Gravimetric method; or | ||
| Australian Standard AS 3580.9.8:2008, Methods for sampling and analysis of ambient air—Determination of suspended particulate matter—PM10 continuous direct mass method using a tapered element oscillating microbalance analyser; or | ||
| Australian/New Zealand Standard AS/NZS 3580.9.11:2008, Methods for sampling and analysis of ambient air—Determination of suspended particulate matter—PM10 beta attenuation monitors | ||
| Sulphur dioxide | Australian Standard AS 3580.4.1:2008, Methods of sampling and analysis of ambient air—Determination of sulfur dioxide—Direct reading instrumental method |
Schedule 2: amended, on 1 June 2011, by regulation 19(1) of the Resource Management (National Environmental Standards for Air Quality) Amendment Regulations 2011 (SR 2011/103).
Schedule 2: amended, on 1 June 2011, by regulation 19(2) of the Resource Management (National Environmental Standards for Air Quality) Amendment Regulations 2011 (SR 2011/103).