Hazardous Substances (Emergency Management) Amendment Regulations 2004
Hazardous Substances (Emergency Management) Amendment Regulations 2004
Checking for alerts... Loading...
Hazardous Substances (Emergency Management) Amendment Regulations 2004
Reprint as at 1 December 2017
Hazardous Substances (Emergency Management) Amendment Regulations 2004
(SR 2004/44)
Hazardous Substances (Emergency Management) Amendment Regulations 2004: revoked, on 1 December 2017, pursuant to regulation 4(1) of the Hazardous Substances (Health and Safety Reform Revocations) Regulations 2017 (LI 2017/233).
Note
Changes authorised by subpart 2 of Part 2 of the Legislation Act 2012 have been made in this eprint. See the notes at the end of this eprint for further details.
These regulations are administered by the Ministry for the Environment.
Pursuant to section 76(1)(d) of the Hazardous Substances and New Organisms Act 1996, Her Excellency the Governor-General, acting on the advice and with the consent of the Executive Council (given on the recommendation of the Minister for the Environment made in compliance with section 141(1) of that Act), makes the following regulations.
Contents
1 Title
(1)
These regulations are the Hazardous Substances (Emergency Management) Amendment Regulations 2004.
(2)
In these regulations, the Hazardous Substances (Emergency Management) Regulations 20011 are called “the principal regulations”
.
2 Commencement
These regulations come into force on 26 March 2004.
3 Interpretation
(1)
Regulation 3(1) of the principal regulations is amended by inserting, before the definition of incompatible, the following definitions:
aerosol has the same meaning as in clause 1 of Schedule 2 of the Hazardous Substances (Classification) Regulations 2001
Authority means the Environmental Risk Management Authority established under section 14 of the Hazardous Substances and New Organisms Act 1996
documentation includes information recorded electronically
hazard classification means a classification under the classification system described in regulation 4 of the Hazardous Substances (Classification) Regulations 2001
(2)
Regulation 3(1) of the principal regulations is amended by omitting from the definition of incompatible the words “regulation 84, or regulation 103”
, and substituting the words “regulation 87, or regulation 105”
.
4 New regulation 4A inserted
The principal regulations are amended by inserting, after regulation 4, the following regulation:
4A Exclusion for fuel gases
(1)
The requirements of these regulations do not apply to any fuel gas supplied or used in a gas distribution system, gas appliance, or gas installation, when subject to the Gas Act 1992.
(2)
In subclause (1),—
fuel gas means any fuel supplied through pipes or in containers that is a gas at 15°C and 101.3 kPa absolute pressure; and includes—
(a)
biogas, coal gas, liquified petroleum gas, natural gas, oil gas, producer gas, refinery gas, and reformed natural gas; and
(b)
any gaseous substance that the Governor-General declares by Order in Council under the Gas Act 1992 to be a gas for the purposes of that Act; and
(c)
any gaseous substance or mixture whose composition complies with regulations under the Gas Act 1992 allowing it to be used as fuel; and
(d)
any mixture of fuel gases
gas appliance has the meaning given to that term by section 2(1) of the Gas Act 1992
gas distribution means a distribution system within the meaning of section 2(1) of the Gas Act 1992
gas installation has the meaning given to that term by section 2(1) of the Gas Act 1992.
(3)
This regulation overrides all other provisions of these regulations.
6 Heading to Part 3 amended
The principal regulations are amended by omitting, from the heading to Part 3, the word “information”
, and substituting the word “documentation”
.
7 Information duties under Part 3 of suppliers
The heading to regulation 12 of the principal regulations is amended by omitting the word “Information”
, and substituting the word “Documentation”
.
8 Certain suppliers to give further information if asked
9 Information duties under Part 3 of persons in charge of places of work
(1)
The heading to regulation 14 of the principal regulations is amended by omitting the word “Information”
, and substituting the word “Documentation”
.
(2)
Regulation 14(1) of the principal regulations is amended by omitting the expression “3.1D, 5.3G, 6.1E, 6.3A, 6.4A, 9.1D, or 9.2D”
wherever it occurs, and substituting in each case the expression “3.1D, 5.2G, 6.1E, 6.3A, 6.3B, 6.4A, 9.1D, or 9.2D”
.
(3)
Regulation 14(2) of the principal regulations is amended by omitting the word “information”
in both places where it occurs, and substituting in each case the word “documentation”
.
10 Alternative information for substances being transported
The heading to regulation 15 of the principal regulations is amended by omitting the word “information”
, and substituting the word “documentation”
.
11 Cross-heading amended
The cross-heading immediately above regulation 16 of the principal regulations is amended by omitting the word “information”
, and substituting the word “documentation”
.
12 General content
The heading to regulation 16 of the principal regulations is amended by adding the words “requirements for documentation”
.
13 Extra content for flammable and oxidising substances and organic peroxides
The heading to regulation 17 of the principal regulations is amended by omitting the words “Extra content”
, and substituting the words “Specific documentation requirements”
.
14 New regulation 18 substituted
The principal regulations are amended by revoking regulation 18 and substituting the following regulation:
18 Location and presentation of documentation
Documentation required by regulation 16 or regulation 17 must be provided in accordance with regulation 48 of the Hazardous Substances (Identification) Regulations 2001, and regulation 48 applies with all necessary modifications.
16 Fire extinguishers required
Regulation 21(3)(a) of the principal regulations is amended by omitting the expression “103 kPa”
, and substituting the expression “101.3 kPa”
.
17 Capability of fire extinguishers
Regulation 23 of the principal regulations is amended by omitting the expression “6 m”
, and substituting the expression “6 m2”
.
18 Duties of persons in charge of places under this Part
Regulation 25(3)(b)(i) of the principal regulations is amended by omitting the expression “103 kPa”
, and substituting the expression “101.3 kPa”
.
19 Extra information required in some cases
Regulation 30(a) of the principal regulations is amended by omitting the words “design and installation”
, and substituting the words “type and location”
.
20 Terms used in regulations 36 to 41
(1)
(2)
Regulation 35 of the principal regulations is amended by revoking the definition of secondary containment system, and substituting the following definition:
secondary containment system, in relation to a place,—
(a)
means a system or systems—
(i)
in which pooling substances held in the place will be contained if they escape from the container or containers in which they are being held; and
(ii)
from which they can, subject to unavoidable wastage, be recovered; and
(b)
includes a system or systems that comply with a code of practice approved by the Authority under section 78 of the Hazardous Substances and New Organisms Act 1996
21 Secondary containment systems for pooling substances
Regulation 36 of the principal regulations is amended by inserting, after subclause (2), the following subclause:
(2A)
If 2 or more containers of different capacities (as described in regulations 37 to 39) are held at one place, the system must have a capacity of at least the sum of each container category.
22 New regulation 40 substituted
The principal regulations are amended by revoking regulation 40, and substituting the following regulation:
40 Below ground containers
(1)
If the pooling substances held in a place are in 1 or more below ground containers, the secondary containment system must have a capacity at least equal to the total pooling potential.
(2)
In subclause (1), below ground container—
(a)
means a container that is situated below ground; and
(b)
includes—
(i)
a container below ground, the level of which has been raised to provide cover for the container; and
(ii)
a container covered by other incombustible material instead of ground.
Schedule New Schedules 1 to 5 substituted in principal regulations
r 23
Schedule 1 Quantities requiring Level 1 information
rr 6, 7(1)
| Hazard classification | Description | Quantity |
|---|---|---|
| 1—all hazard classifications except the following: | gas, liquid, or solid | any quantity |
| (a) safety ammunition, including pre-primed cartridges and primers, of class 1.4S; and | ||
| (b) airbag initiators and seatbelt pretensioners of classes 1.4G and 1.4S; and | ||
| (c) fireworks subject to the Hazardous Substances (Fireworks) Regulations 2001; and | ||
| (d) cable cutters of class 1.4S (UN 0070); and | ||
| (e) power device cartridges of class 1.4S (UN 0323): and | ||
| (f) signal or shock tubes of class 1.4S (UN 0349); and | ||
| (g) cassette degradation devices of class 1.4S (UN 0432): and | ||
| (h) emergency flares and signalling devices of classes 1.3 G, 1.4G, and 1.4S: and | ||
| (i) model rocket motors of classes 1.4G and 1.4S; and | ||
| (j) igniting fuzes of class 1.4G (UN 0317); and | ||
| (k) igniters of class 1.4S (UN 0454). | ||
| 2.1.1A | non-permanent gas | 0.2 kg |
| permanent gas | 0.2 m3 | |
| 2.1.1B | non-permanent gas | 0.5 kg |
| permanent gas | 0.5 m3 | |
| 2.1.2A | aerosol | 1.0 L aggregate water capacity |
| 3.1A | liquid | 0.5 L |
| 3.1B, 3.1C | liquid | 1.0 L |
| 3.1D | liquid | 5.0 L |
| 3.2A, 3.2B, 3.2C | liquid | 0.2 L |
| 4.1.1A | solid | 0.5 kg |
| 4.1.1B | solid | 1.0 kg |
| 4.1.2A, 4.1.2B, 4.1.2C, 4.1.2D, 4.1.2E, 4.1.2F, 4.1.2G | liquid | 0.2 L |
| solid | 0.2 kg | |
| 4.1.3A, 4.1.3B, 4.1.3C | liquid | 0.2 L |
| solid | 0.2 kg | |
| 4.2A | liquid | 0.2 L |
| solid | 0.2 kg | |
| 4.2B | solid | 0.5 kg |
| 4.2C | solid | 1.0 kg |
| 4.3A | liquid | 0.2 L |
| solid | 0.2 kg | |
| 4.3B | liquid | 0.5 L |
| solid | 0.5 kg | |
| 4.3C | liquid | 1.0 L |
| solid | 1.0 kg | |
| 5.1.1A | liquid | 0.2 L |
| solid | 0.2 kg | |
| 5.1.1B | liquid | 0.5 L |
| solid | 0.5 kg | |
| 5.1.1C | liquid | 1.0 L |
| solid | 1.0 kg | |
| 5.1.2A | non-permanent gas | 1.0 kg |
| permanent gas | 1.0 m3 | |
| 5.2A, 5.2B, 5.2C, 5.2D | liquid | 0.1 L |
| solid | 0.1 kg | |
| 5.2E, 5.2F | liquid | 0.5 L |
| solid | 0.5 kg | |
| 5.2G | liquid | 5.0 L |
| solid | 5.0 kg | |
| 6.1A, 6.1B, 6.1C | gas, liquid, or solid | any quantity |
| 6.1D, 6.3A, 6.4A | non-permanent gas | 0.1 kg |
| permanent gas | 0.1 m3 | |
| liquid | 0.1 L | |
| solid | 0.1 kg | |
| 6.1E, 6.3B, 6.5A, 6.5B | liquid | 1.0 L |
| solid | 1.0 kg | |
| 8.1A, 8.2B | gas, liquid, or solid | any quantity |
| 8.2C, 8.3A | non-permanent gas | 0.1 kg |
| permanent gas | 0.1 m3 | |
| liquid | 0.1 L | |
| solid | 0.1 kg | |
| 9.1A, 9.2A, 9.3A, 9.4A | liquid | 0.1 L |
| solid | 0.1 kg | |
| 9.1B, 9.2B, 9.3B, 9.4B | liquid | 0.2 L |
| solid | 0.2 kg | |
| 9.1C, 9.1D, 9.2C, 9.2D, 9.3C, 9.4C | liquid | 1.0 L |
| solid | 1.0 kg | |
| (All liquid volumes measured at 20°C) | ||
Schedule 2 Quantities requiring Level 2 documentation
rr 12, 14(1)
| Hazard classification | Description | Quantity |
|---|---|---|
| The following class 1: | gas, liquid, or solid | 5 kg (gross weight) per package |
| (a) airbag initiators and seatbelt pretensioners of classes 1.4G or 1.4S: and | ||
| (b) cable cutters of class 1.4S (UN 0070); and | ||
| (c) power device cartridges of class 1.4S (UN 0323); and | ||
| (d) signal or shock tubes of class 1.4S(UN 0349); and | ||
| (e) cassette degradation devices of class 1.4S (UN 0432): and | ||
| (f) emergency flares and signalling devices of classes 1.3G, 1.4G, and 1.4S; and | ||
| (g) model rocket motors of class 1.4G and 1.4S; and | ||
| (h) igniting fuzes of class 1.4G (UN 0317); and | ||
| (i) igniters of class 1.4S (UN 0454). | ||
| The rest of class 1 except— | gas, liquid, or solid | any quantity |
| (a) fireworks subject to the Hazardous Substances (Fireworks) Regulations 2001; and | ||
| (b) safety ammunition, including pre-primed cartridges and primers, of class 1.4S. | ||
| 2.1.1A | non-permanent gas | 0.2 kg |
| permanent gas | 0.2 m3 | |
| 2.1.1B | non-permanent gas | 0.5 kg |
| permanent gas | 0.5 m3 | |
| 2.1.2A | aerosol | 1.0 L aggregate water capacity |
| 3.1A | liquid | 0.5 L |
| 3.1B | liquid | 1.0 L |
| 3.1C | liquid | 5.0 L |
| 3.1D | liquid | 5.0 L |
| 3.2A, 3.2B, 3.2C | liquid | any quantity |
| 4.1.1A | solid | 0.5 kg |
| 4.1.1B | solid | 3.0 kg |
| 4.1.2A, 4.1.2B, 4.1.2C, 4.1.2D, 4.1.2E, 4.1.2F, 4.1.2G | liquid or solid | any quantity |
| 4.1.3A, 4.1.3B, 4.1.3C | liquid or solid | any quantity |
| 4.2A | liquid or solid | any quantity |
| 4.2B | solid | 0.5 kg |
| 4.2C | solid | 3.0 kg |
| 4.3A | liquid or solid | any quantity |
| 4.3B | liquid | 0.5 L |
| solid | 0.5 kg | |
| 4.3C | liquid | 1.0 L |
| solid | 1.0 kg | |
| 5.1.1A | liquid or solid | any quantity |
| 5.1.1B | liquid | 0.5 L |
| solid | 0.5 kg | |
| 5.1.1C | liquid | 1.0 L |
| solid | 1.0 kg | |
| 5.1.2A | non-permanent gas | 1.0 kg |
| permanent gas | 1.0 m3 | |
| 5.2A | liquid or solid | any quantity |
| 5.2B, 5.2C, 5.2D, 5.2E, 5.2F—if substance needs temperature control under the Hazardous Substances (Classes 1 to 5 Controls) Regulations 2001 | liquid or solid | any quantity |
| 5.2B, 5.2C—if substance does not need temperature control under the Hazardous Substances (Classes 1 to 5 Controls) Regulations 2001 | liquid | 25 mL |
| solid | 0.1 kg | |
| 5.2D, 5.2E, 5.2F—if substance does not need temperature control under the Hazardous Substances (Classes 1 to 5 Controls) Regulations 2001 | liquid | 125 mL |
| solid | 0.5 kg | |
| 5.2G | liquid | 50 L |
| solid | 50 kg | |
| 6.1A, 6.1B | gas, liquid, or solid | any quantity |
| 6.1C, 6.6A, 6.7A, 6.8A, 6.9A | non-permanent gas | 0.1 kg |
| permanent gas | 0.1 m3 | |
| liquid | 0.1 L | |
| solid | 0.5 kg | |
| 6.1D, 6.5A, 6.5B, 6.6B, 6.7B, 6.8B, 6.8C, 6.9B | non-permanent gas | 1.0 kg |
| permanent gas | 1.0 m3 | |
| liquid | 1.0 L | |
| solid | 3.0 kg | |
| 6.1E, 6.3A, 6.3B, 6.4A | liquid | 50 L |
| solid | 50 kg | |
| 8.2A | gas, liquid, or solid | any quantity |
| 8.2B | non-permanent gas | 0.5 kg |
| permanent gas | 0.5 m3 | |
| liquid | 0.5 L | |
| solid | 1.0 kg | |
| 8.1A, 8.2C, 8.3A | non-permanent gas | 1.0 kg |
| permanent gas | 1.0 m3 | |
| liquid | 1.0 L | |
| solid | 2.0 kg | |
| 9.1A, 9.1B, 9.1C, 9.2A, 9.2B, 9.2C, 93A, 9.3B, 9.3C, 9.4A, 9.4B, 9.4C | liquid | 5.0 L |
| solid | 5.0 kg | |
| 9.1 D, 9.2D | liquid | 50 L |
| solid | 50 kg | |
| (All liquid volumes measured at 20°C) | ||
Schedule 3 Quantities requiring fire extinguishers
r 21(1)
| Hazard classification | Description | Quantity | No |
|---|---|---|---|
| 1.1A, 1.1B, 1.2B | solid | 1 kg | 1 |
| 1.1C, 1.1D, 1.1E 1.1F, 1.1G, 1.1J, 1.1L, 1.2C, 1.2D, 1.2E, 1.2F, 1.2G, 1.2H, 1.2J, 1.2K, 1.2L, 1.3C, 1.3F, 1.3G, 1.3H, 1.3J, 1.3K, 1.3L | liquid | 25 L | 1 |
| solid | 25 kg | ||
| 1.4B, 1.4C, 1.4D, 1.4E, 1.4F, 1.4G, 1.4S, 1.5D, 1.6N | solid | 50 kg | 1 |
| Fireworks subject to the Hazardous Substances (Fireworks) Regulations 2001 | solid | 300 kg (gross weight) | 1 |
| Safety ammunition, including pre-primed cartridges and primers, of class 1.4S | solid | 500 kg (gross weight) | 1 |
| 2.1.1A | non-permanent gas | 50 kg | 1 |
| permanent gas | 30 m3 | ||
| 2.1.1B | non-permanent gas | 200 kg | 2 |
| permanent gas | 120 m3 | ||
| 2.1.2A | aerosol | 3 000 L aggregate water capacity | 1 |
| 3.1A | liquid | 50 L | 1 |
| 200 L | 2 | ||
| 3.1B | liquid | 250 L | 2 |
| 3.1C, 3.1D | liquid | 500 L | 2 |
| 3.2A, 3.2B, 3.2C | liquid | 50 L | 1 |
| 200 L | 2 | ||
| 4.1.1A | solid | 250 kg | 2 |
| 4.1.1B | solid | 500 kg | 2 |
| 4.1.2A, 4.1.2B, 4.1.2C, 4.1.2D, 4.1.2E, 4.1.2F, 4.1.2G | liquid | 50 L | 1 |
| 200 L | 2 | ||
| solid | 50 kg | 1 | |
| 200 kg | 2 | ||
| 4.1.3A, 4.1.3B, 4.1.3C | liquid | 50 L | 1 |
| 200 L | 2 | ||
| solid | 50 kg | 1 | |
| 200 kg | 2 | ||
| 4.2A | liquid | 50 L | 1 |
| 200 L | 2 | ||
| solid | 50 kg | 1 | |
| 200 kg | 2 | ||
| 4.2B | solid | 250 kg | 2 |
| 4.2C | solid | 500 kg | 2 |
| 4.3A | liquid | 50 L | 1 |
| 200 L | 2 | ||
| solid | 50 kg | 1 | |
| 200 kg | 2 | ||
| 4.3B | liquid | 250 L | 2 |
| solid | 250 kg | ||
| 4.3C | liquid | 500 L | 2 |
| solid | 500 kg | ||
| 5.1.1A | liquid | 5 L | 1 |
| solid | 5 kg | ||
| 5.1.1B | liquid | 200 L | 1 |
| solid | 200 kg | ||
| 5.1.1C | liquid | 500 L | 2 |
| solid | 500 kg | ||
| 5.1.2A | non-permanent gas | 10 kg | 1 |
| 50 kg | 2 | ||
| permanent gas | 10 m3 | 1 | |
| 50 m3 | 2 | ||
| 5.2A, 5.2B | liquid | 1 L | 1 |
| solid | 1 kg | ||
| 5.2C, 5.2D | liquid | 10 L | 1 |
| solid | 10 kg | ||
| 5.2E, 5.2F | liquid | 50 L | 1 |
| solid | 50 kg |
Schedule 4 Threshold quantities for Level 3
r 25(1)
| Hazard classification | Description | Quantity |
|---|---|---|
| 1.1A, 1.1B, 1.1C, 1.1D, 1.1E, 1.1F, 1.1G, 1.1J, 1.1L, 1.2B, 1.2C, 1.2D, 1.2E, 1.2F, 1.2G, 1.2H, 1.2J 1.2K, 1.2L | liquid | 50 L |
| solid | 50 kg | |
| 1.3C, 1.3F, 1.3G, 1.3H, 1.3J, 1.3K, 1.3L | liquid | 100 L |
| solid | 100 kg | |
| 1.4B, 1.4C, 1.4D, 1.4E, 1.4F, 1.4G, 1.4S, 1.5D, 1.6N, except the following: | liquid | 200 L |
| solid | 200 kg | |
| (a) fireworks subject to the Hazardous Substances (Fireworks) Regulations 2001: and | ||
| (b) safety ammunition, including pre-primed cartridges and primers, of class 1.4S; and | ||
| (c) airbag initiators and seatbelt pretensioners of classes 1.4G and 1.4S: and | ||
| (d) cable cutters of class 1.4S (UN 0070); and | ||
| (e) power device cartridges of class 1.4S (UN 0323); and | ||
| (f) signal or shock tubes of class 1.4S (UN 0349); and | ||
| (g) cassette degradation devices of class 1.4S (UN 0432); and | ||
| (h) emergency flares and signalling devices of classes 1.3G, 1.4G, and 1.4S, | ||
| 2.1.1A | non-permanent gas | 300 kg |
| permanent gas | 200 m3 | |
| 2.1.1B | non-permanent gas | 1 000 kg |
| permanent gas | 600 m3 | |
| 2.1.2A | aerosol | 3 000 L aggregate water capacity |
| 3.1A | liquid | 100 L |
| 3.1B | liquid | 1 000 L |
| 3.1C, 3.1D | liquid | 10 000 L |
| 3.2A, 3.2B, 3.2C | liquid | 100 L |
| 4.1.1A | solid | 1 000 kg |
| 4.1.1B | solid | 10 000 kg |
| 4.1.2A, 4.1.2B | liquid | 50 L |
| solid | 50 kg | |
| 4.1.2C, 4.1.2D | liquid | 100 L |
| solid | 100 kg | |
| 4.1.2E, 4.1.2F, 4.1.2G | liquid | 200 L |
| solid | 200 kg | |
| 4.1.3A, 4.1.3B, 4.1.3C | liquid | 100 L |
| solid | 100 kg | |
| 4.2A | liquid | 100 L |
| solid | 100 kg | |
| 4.2B | solid | 1 000 kg |
| 4.2C | solid | 10 000 kg |
| 4.3A | liquid | 100 L |
| solid | 100 kg | |
| 4.3B | liquid | 1 000 L |
| solid | 1 000 kg | |
| 4.3C | liquid | 10 000 L |
| solid | 10 000 kg | |
| 5.1.1A | liquid | 50 L |
| solid | 50 kg | |
| 5.1.1B | liquid | 500 L |
| solid | 500 kg | |
| 5.1.1C | liquid | 5 000 L |
| solid | 5 000 kg | |
| 5.1.2A | non-permanent gas | 100 kg |
| permanent gas | 100 m3 | |
| 5.2A, 5.2B | liquid | 10 L |
| solid | 10 kg | |
| 5.2C, 5.2D | liquid | 25 L |
| solid | 25 kg | |
| 5.2E 5.2F | liquid | 100 L |
| solid | 100 kg | |
| 6.1A, 6.1B, 6.1C | non-permanent gas | 5 kg |
| permanent gas | 2.5 m3 | |
| liquid | 100 L | |
| solid | 100 kg | |
| 6.1D, 6.5A, 6.5B, 6.7A | non-permanent gas | 50 kg |
| permanent gas | 25 m3 | |
| liquid | 1 000 L | |
| solid | 1 000 kg | |
| 6.6A, 6.7B, 6.8A, 6.9A | liquid | 10 000 L |
| solid | 10 000 kg | |
| 8.2A | non-permanent gas | 5 kg |
| permanent gas | 2.5 m3 | |
| liquid | 100 L | |
| solid | 100 kg | |
| 8.2B | non-permanent gas | 50 kg |
| permanent gas | 25 m3 | |
| liquid | 1 000 L | |
| solid | 1 000 kg | |
| 8.2C, 8.3A | liquid | 10 000 L |
| solid | 10 000 kg | |
| 9.1A | liquid | 100 L |
| solid | 100 kg | |
| 9.1B, 9.1C | liquid | 1 000 L |
| solid | 1 000 kg | |
| 9.1D | liquid | 10 000 L |
| solid | 10 000 kg |
Schedule 5 Quantities requiring signage
r 42
| Hazard classification | Description | Quantity |
|---|---|---|
| 1 | Fireworks subject to the Hazardous Substances (Fireworks) Regulations 2001 | 1 000 kg (gross weight) |
| Safety ammunition, including pre-primed cartridges and primers, of class 1.4S | 10 000 kg (gross weight) | |
| Airbag initiators and seatbelt pretensioners of class 1.4G and 1.4S | 5 000 kg (gross weight) | |
| Cable cutters of class 1.4S (UN 0070) | 5 000 kg (gross weight) | |
| Power device cartridges of class 1.4S (UN 0323) | 5 000 kg (gross weight) | |
| Signal or shock tubes of class 1.4S (UN 0349) | 5 000 kg (gross weight) | |
| Cassette degradation devices of class 1.4S(UN 0432) | 5 000 kg (gross weight) | |
| Propellants of class 1.1C (UN 0160) and 1.3C (UN 0161 and UN 0499), gun-powder of class 1.1D (UN 0027), and substances of classes 1.3G, 1.4G, and 1.4S not listed above | 50 kg | |
| All remaining explosive hazardous classifications | any quantity | |
| 2.1.1A | non-permanent gas | 250 kg |
| permanent gas | 100 m3 | |
| 2.1.1B | non-permanent gas | 500 kg |
| permanent gas | 200 m3 | |
| 2.1.2A | aerosol | 3 000 L aggregate water capacity |
| 3.1A, 3.2A, 4.1.3A, 4.2A, 4.3A | liquid | 50 L |
| solid | 50 kg | |
| 3.1B, 3.2B, 4.1.3B, 4.2B, 4.3B | liquid | 250 L |
| solid | 250 kg | |
| 3.1C, 3.2C, 4.1.3C, 4.2C, 4.3C | liquid | 1 000 L |
| solid | 1 000 kg | |
| 3.1D | liquid | 10 000 L |
| 4.1.1A | solid | 250 kg |
| 4.1.1B | solid | 1 000 kg |
| 4.1.2A, 4.1.2B | liquid | 50 L |
| solid | 50 kg | |
| 4.1.2C, 4.1.2D | liquid | 250 L |
| solid | 250 kg | |
| 4.1.2E, 4.1.2F, 4.1.2G | liquid | 1 000 L |
| solid | 1 000 kg | |
| 5.1.1A | liquid | 50 L |
| solid | 50 kg | |
| 5.1.1B | liquid | 500 L |
| solid | 500 kg | |
| 5.1.1C | liquid | 1 000 L |
| solid | 1 000 kg | |
| 5.1.2A | non-permanent gas | 250 kg |
| permanent gas | 500 m3 | |
| 5.2A, 5.2B | liquid | 1 L |
| solid | 1 kg | |
| 5.2C, 5.2D, 5.2E, 5.2F | liquid | 10 L |
| solid | 10 kg | |
| 6.1A | liquid | 50 L |
| solid | 50 kg | |
| 6.1B | liquid | 250 L |
| solid | 250 kg | |
| 6.1C | liquid | 1 000 L |
| solid | 1 000 kg | |
| 6.1D | liquid | 10 000 L |
| solid | 10 000 kg | |
| 6.1A, 6.1B. 6.1C | non-permanent gas | 5 kg |
| permanent gas | 2.5 m3 | |
| 8.1A | liquid | 1 000 L |
| solid | 1 000 kg | |
| 8.2A | non-permanent gas | 5 kg |
| permanent gas | 2.5 m3 | |
| liquid | 50 L | |
| solid | 50 kg | |
| 8.2B | non-permanent gas | 50 kg |
| permanent gas | 25 m3 | |
| liquid | 250 L | |
| solid | 250 kg | |
| 8.2C, 8.3A | liquid | 1 000 L |
| solid | 1 000 kg | |
| 9.1A, 9.2A, 9.3A, 9.4A | liquid | 100 L |
| solid | 100 kg | |
| 9.1B, 9.1C, 9.2B, 9.2C, 9.3B, 9.4B, 9.4C | liquid | 1 000 L |
| solid | 1 000 kg | |
| 9.1D, 9.2D, 9.3C | liquid | 10 000 L |
| solid | 10 000 kg |
Diane Morcom,
Clerk of the Executive Council.
Explanatory note
This note is not part of the regulations, but is intended to indicate their general effect.
These regulations, which come into force on 26 March 2004, amend the Hazardous Substances (Emergency Management) Regulations 2001—
to account for the transfer of dangerous goods from current regulatory regimes, or transitional regimes under the Hazardous Substances and New Organisms Act 1996, to permanent control under the Hazardous Substances and New Organisms Act 1996:
to correct cross-references and minor technical and drafting errors.
Issued under the authority of the Legislation Act 2012.
Date of notification in Gazette: 4 March 2004.
Eprint notes
1 General
This is an eprint of the Hazardous Substances (Emergency Management) Amendment Regulations 2004 that incorporates all the amendments to those regulations as at the date of the last amendment to them.
2 About this eprint
This eprint is not an official version of the legislation under section 18 of the Legislation Act 2012.
3 Amendments incorporated in this eprint
Hazardous Substances (Health and Safety Reform Revocations) Regulations 2017 (LI 2017/233): regulation 4(1)
1 SR 2001/123
"Related Legislation
"Related Legislation
"Related Legislation
Versions
Hazardous Substances (Emergency Management) Amendment Regulations 2004
RSS feed link copied, you can now paste this link into your feed reader.